Heavy Duty Chemical / Flame resistant Suit

Product Details
- Two-piece integrated design, the outer layer is made of aramid fiber aluminized layer, and the inner layer is made of high-barrier multi-component rubber material.
- The inner layer of chemical protective clothing is designed with a ventilation and moisture removal system.
- The seams are made of the same chemical-resistant material as the fabric
- The overall performance complies with the standards of GA634-2015 "Heat Insulation Protective Clothing for Firefighters" and GA770-2008 "Chemical Protective Clothing for Firefighters".
- Hydrostatic pressure resistance ≥ 200kPa.
- Flame burning time ≤ 0.2s, flameless burning time ≤ 0.1s, damage length ≤ 4.2cm;
- Protection time against industrial chemicals: dimethyl sulfate ≥ 90min; ammonia ≥ 90min; chlorine ≥ 90min; cyanide chloride ≥ 90min; carbonyl chloride ≥ 90min; hydrogen cyanide ≥ 90min.
- Resistance to chemical penetration: penetration time in acid solutions of 98% sulfuric acid, 60% nitric acid, 30% hydrochloric acid, and 40% sodium hydroxide> 70min